Sign In | Join Free | My ccnmag.com |
|
Brand Name : BT Lab
Model Number : Cat.No E0792Mo
Certification : CE, ISO9001:2005, MSDS
Place of Origin : Shanghai, China
MOQ : Negotiation
Price : Negotiation
Payment Terms : Western Union, T/T
Supply Ability : In Stock
Delivery Time : 1-3 business days, bulk order within one week
Packaging Details : Wrapped with ice pack and styrofoam package
Brand : BT Lab
Assay Time : 2 hours
Sample : serum,plasma,urine,tissue,cell culture supernatant
Custom : Available
Organism Species : mouse
OEM : Acceptable
96 Wells Mouse Activin A ACV-A ELISA Kit Sensitivity and Specificity
Cat.No E0792Mo
Standard Curve Range: 10ng/L - 3000ng/L
Sensitivity: 5.43ng/L
Size: 96 wells
Assay Principle
This kit is an Enzyme-Linked Immunosorbent Assay (ELISA). The plate has been pre-coated with Mouse ACV-A antibody. ACV-A present in the sample is added and binds to antibodies coated on the wells. And then biotinylated Mouse ACV-A Antibody is added and binds to ACV-A in the sample. Then Streptavidin-HRP is added and binds to the Biotinylated ACV-A antibody. After incubation unbound Streptavidin-HRP is washed away during a washing step. Substrate solution is then added and color develops in proportion to the amount of Mouse ACV-A. The reaction is terminated by addition of acidic stop solution and absorbance is measured at 450 nm.
Reagent Provided
Components | Quantity |
Standard Solution (3200ng/L) | 0.5ml x1 |
Pre-coated ELISA Plate | 12 * 8 well strips x1 |
Standard Diluent | 3ml x1 |
Streptavidin-HRP | 6ml x1 |
Stop Solution | 6ml x1 |
Substrate Solution A | 6ml x1 |
Substrate Solution B | 6ml x1 |
Wash Buffer Concentrate (30x) | 20ml x1 |
Biotinylated Mouse ACV-A Antibody | 1ml x1 |
User Instruction | 1 |
Plate Sealer | 2 pics |
Zipper bag | 1 pic |
Material Required But Not Supplied
Reagent Preparation
All reagents should be brought to room temperature before use.
Standard Reconstitute the 120μl of the standard (3200ng/L) with 120μl of standard diluent to generate a 1600ng/L standard stock solution. Allow the standard to sit for 15 mins with gentle agitation prior to making dilutions. Prepare duplicate standard points by serially diluting the standard stock solution (1600ng/L) 1:2 with standard diluent to produce 800ng/L, 400ng/L, 200ng/L and 100ng/L solutions. Standard diluent serves as the zero standard(0 ng/L). Any remaining solution should be frozen at -20°C and used within one month. Dilution of standard solutions suggested are as follows:
1600ng/L | Standard No.5 | 120μl Original Standard + 120μl Standard Diluent |
800ng/L | Standard No.4 | 120μl Standard No.5 + 120μl Standard Diluent |
400ng/L | Standard No.3 | 120μl Standard No.4 + 120μl Standard Diluent |
200ng/L | Standard No.2 | 120μl Standard No.3 + 120μl Standard Diluent |
100ng/L | Standard No.1 | 120μl Standard No.2 + 120μl Standard Diluent |
Standard Concentration | Standard No.5 | Standard No.4 | Standard No.3 | Standard No.2 | Standard No.1 |
3200ng/L | 1600ng/L | 800ng/L | 400ng/L | 200ng/L | 100ng/L |
Wash Buffer Dilute 20ml of Wash Buffer Concentrate 30x into deionized or distilled water to yield 500 ml of 1x Wash Buffer. If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved.
Summary
1. Prepare all reagents, samples and standards.
2. Add sample and ELISA reagent into each well. Incubate for 1 hour at 37°C.
3. Wash the plate 5 times.
4. Add substrate solution A and B. Incubate for 10 minutes at 37°C.
5. Add stop solution and color develops.
6. Read the OD value within 10 minutes.
Calculation of Result
Construct a standard curve by plotting the average OD for each standard on the vertical (Y) axis against the concentration on the horizontal (X) axis and draw a best fit curve through the points on the graph. These calculations can be best performed with computer-based curve-fitting software and the best fit line can be determined by regression analysis.
![]() |